Pipeline
- 01BriefDone88 rooms · 2 levels · assumptions listed
- 02Code checkReview4/4 code checks pass · audit 14 pass · 0 warn · 0 fail · ⚠ verify flags
- 03DrawingsDoneDXF · DWG · PDF · AutoCAD AUDIT 0
- 04MEPDoneMEP overlay · AutoCAD AUDIT 0
- 05BIMDoneIFC 274.5 KB · 0 validation issues · 406 elements
- 06RenderDone1 image
- 07QA reviewMissingno qa-review.md
Key numbers
10,800m²Plot area
6,866m²Footprint
63.6%Coverage
2Levels
88Rooms
6,935m²Gross lettable area
8 + 12Shops per level
51.6mMax travel to exit
Gallery
Renders
Drawings
Code check
4 PASS
| Check | Design | Limit | Result |
|---|---|---|---|
| South front setback | 15.45 m | ≥ 5.00 m | PASS |
| North rear setback | 11.85 m | ≥ 3.00 m | PASS |
| West side setback | 5.25 m | ≥ 3.00 m | PASS |
| East side setback | 5.25 m | ≥ 3.00 m | PASS |
Source: ASSUMED 5/3/3 m - no commercial-zone setbacks in country file [verify] ⚠ verify
Design parameters
Travel distance to exitmax 51.6 m ≤ 76.2 mPASSus.md 5.3 IBC Table 1017.2 M sprinklered 250 ft ⚠ verify
Parking shown vs required45 of 299 baysWARNus.md 5.5 retail 1 per 250 sq ft ⚠ verify
Stair clear width1.12 mPASSus.md 5.3 IBC 1011.2 commercial stair 44 in
Ground-floor height5.0 mPASSrule of thumb 4.5-5.5 m GF floor-to-floor ⚠ verify
Sprinkler designNFPA 13 OH2 · 12.1 m² / 4.6 mPASSreferences/disciplines/mep.md 4.1
Notes & assumptions
- SAMPLE PROJECT generated by ArchMind gen_mall.py - not for submission.
- GRID 8.4 m [RoT retail 7.5-9 m]; street 12 m, shops 8.4 x 21 m, service corridor 4.2 m [RoT].
- TRAVEL LIMIT 76.2 m: us.md 5.3 IBC Table 1017.2 M sprinklered 250 ft (verify). Computed max this level 42.1 m.
- Exit = final exit door or protected-stair door; path around atrium void; open-plan rooms; sprinklered building (assumed).
- SETBACKS F/S/R 5/3/3 m: ASSUMED 5/3/3 m - no commercial-zone setbacks in country file (verify)
- ASSUMPTIONS: plot 120 x 90 m, frontage south, loading yard north; service corridors fire-rated, 2+ exits each.
- WC separated men/women, accessible WC every level (RoT).
- Stairs, escalators, atrium void: see MEP/ARCH overlay.
Design audit
7 PASS
| Result | Check | Finding |
|---|---|---|
| PASS | rooms | 42 rooms matched to 42 enclosed polygons; net areas within 5% of spec |
| PASS | circulation | 114 doors; all 42 rooms reachable from OUTSIDE |
| PASS | doors | 114 doors / 37 windows: placement, swings and overlaps OK |
| PASS | dead-space | no dead-end corridor/hall over 6 m2 |
| PASS | sizes | area/width minima: references/countries/us.md (IRC R304: 70 sq ft, 7 ft; marked verify); other types generic rule of thumb (lower bound of architecture.md section 3 typical range) |
| PASS | habitability | every habitable room has a window to OUTSIDE/courtyard; no WC/bath door straight into kitchen/dining/majlis |
| PASS | privacy | not applicable (country 'us' is not a Gulf profile) |
7 PASS
| Result | Check | Finding |
|---|---|---|
| PASS | rooms | 46 rooms matched to 46 enclosed polygons; net areas within 5% of spec |
| PASS | circulation | 114 doors; all 46 rooms reachable from OUTSIDE |
| PASS | doors | 114 doors / 38 windows: placement, swings and overlaps OK |
| PASS | dead-space | no dead-end corridor/hall over 6 m2 |
| PASS | sizes | area/width minima: references/countries/us.md (IRC R304: 70 sq ft, 7 ft; marked verify); other types generic rule of thumb (lower bound of architecture.md section 3 typical range) |
| PASS | habitability | every habitable room has a window to OUTSIDE/courtyard; no WC/bath door straight into kitchen/dining/majlis |
| PASS | privacy | not applicable (country 'us' is not a Gulf profile) |
Verification
AutoCAD · GF MEPAUDIT 0 errors
- AUDIT errors
- 0
- On layer 0
- 0
- Entities
- 6782
- Layers
- 37
- Dimensions
- 24
- Texts
- 433
- Hatches
- 172
- Layout
- ARCH-D
- ACAD version
- 25.1
AutoCAD · GF PlanAUDIT 0 errors
- AUDIT errors
- 0
- On layer 0
- 0
- Entities
- 1271
- Layers
- 14
- Dimensions
- 24
- Texts
- 150
- Hatches
- 172
- Layout
- ARCH-D
- ACAD version
- 25.1
IFC modelvalid
- Wall
- 57
- Door
- 114
- Window
- 37
- OpeningElement
- 151
- Slab
- 5
- Space
- 42
- Validation issues
- 0
Room schedule
| Room | Area m² |
|---|---|
| MALL STREET & ATRIUM | 1,491.6 |
| LIFTS | 10.8 |
| LIFTS | 10.8 |
| ANCHOR STORE W | 1,026.2 |
| ANCHOR STORE E | 1,026.2 |
| SERVICE CORRIDOR SW1 | 65.4 |
| SERVICE CORRIDOR SE2 | 98.6 |
| SERVICE CORRIDOR NW1 | 131.5 |
| SERVICE CORRIDOR NE2 | 98.3 |
| ESCAPE STAIR 1 | 66.4 |
| PASSAGE 1 | 45.4 |
| ELEC RISER 1 | 41.8 |
| MECH RISER 1 | 42.0 |
| SHOP 01 | 170.0 |
| SHOP 02 | 170.6 |
| SHOP 03 | 170.6 |
| SHOP 04 | 170.6 |
| SHOP 05 | 170.0 |
| SHOP 06 | 170.0 |
| SHOP 07 | 170.6 |
| LINK | 28.4 |
| ACCESS WC | 5.7 |
| MEN WC | 30.1 |
| WOMEN WC | 29.8 |
| BABY CARE | 34.5 |
| FIRST AID | 34.2 |
| MDB | 82.0 |
| FIRE PUMP | 82.0 |
| LOADING BAY | 203.1 |
| AHU PLANT | 82.0 |
| GEN SET | 82.0 |
| LINK | 28.4 |
| ACCESS WC | 5.7 |
| MEN WC | 29.8 |
| WOMEN WC | 30.1 |
| BABY CARE | 34.2 |
| FIRST AID | 34.5 |
| SHOP 08 | 170.0 |
| ESCAPE STAIR 2 | 66.4 |
| PASSAGE 2 | 45.4 |
| ELEC RISER 2 | 41.8 |
| MECH RISER 2 | 42.0 |
| Total · 42 rooms | 6,569.5 |
| Room | Area m² |
|---|---|
| MALL STREET & FOOD COURT | 1,378.0 |
| LIFTS | 10.8 |
| LIFTS | 10.8 |
| FOOD 01 | 26.3 |
| FOOD 02 | 26.4 |
| FOOD 03 | 26.4 |
| FOOD 04 | 26.3 |
| ANCHOR STORE W | 1,026.2 |
| ANCHOR STORE E | 1,026.2 |
| SERVICE CORRIDOR SW1 | 65.4 |
| SERVICE CORRIDOR SE2 | 98.6 |
| SERVICE CORRIDOR NW1 | 131.5 |
| SERVICE CORRIDOR NE2 | 98.3 |
| ESCAPE STAIR 1 | 66.4 |
| PASSAGE 1 | 45.4 |
| ELEC RISER 1 | 41.8 |
| MECH RISER 1 | 42.0 |
| SHOP 01 | 170.0 |
| SHOP 02 | 170.6 |
| SHOP 03 | 170.6 |
| SHOP 04 | 170.6 |
| SHOP 05 | 170.0 |
| SHOP 06 | 170.0 |
| SHOP 07 | 170.6 |
| LINK | 28.4 |
| ACCESS WC | 5.7 |
| MEN WC | 30.1 |
| WOMEN WC | 29.8 |
| BABY CARE | 34.5 |
| FIRST AID | 34.2 |
| MDB | 82.0 |
| FIRE PUMP | 82.0 |
| LOADING BAY | 203.1 |
| AHU PLANT | 82.0 |
| GEN SET | 82.0 |
| LINK | 28.4 |
| ACCESS WC | 5.7 |
| MEN WC | 29.8 |
| WOMEN WC | 30.1 |
| BABY CARE | 34.2 |
| FIRST AID | 34.5 |
| SHOP 08 | 170.0 |
| ESCAPE STAIR 2 | 66.4 |
| PASSAGE 2 | 45.4 |
| ELEC RISER 2 | 41.8 |
| MECH RISER 2 | 42.0 |
| Total · 46 rooms | 6,561.3 |
Downloads
| File | Level | Size |
|---|---|---|
| DWGGF.dwg | GF | 68.3 KB |
| DXFGF.dxf | GF | 426.8 KB |
| PDFGF.pdf | GF | 151.4 KB |
| IFCGF.ifc | GF | 274.5 KB |
| JSONGF.json | GF | 36.4 KB |
| TXTGF-audit.txt | GF | 753 B |
| TXTGF-report.txt | GF | 136 B |
| DWGGF-MEP.dwg | GF · MEP | 182.5 KB |
| PDFGF-MEP.pdf | GF · MEP | 242.7 KB |
| TXTGF-MEP-report.txt | GF · MEP | 136 B |
| JSONL1.json | L1 | 32.9 KB |
| TXTL1-audit.txt | L1 | 753 B |
| JSONmall.json | Project | 2.5 KB |
| ZIPextra-dxf.zip 3 files: L1.dxf, L1-MEP.dxf, GF-MEP.dxf | Project | 242.6 KB |
| TXTifc.txt | Project | 159 B |
| 15 files | 1.6 MB |