plan_audit: examples/malls/sa/GF.json country=sa PASS [rooms] 42 rooms matched to 42 enclosed polygons; net areas within 5% of spec PASS [circulation] 114 doors; all 42 rooms reachable from OUTSIDE PASS [doors] 114 doors / 37 windows: placement, swings and overlaps OK PASS [dead-space] no dead-end corridor/hall over 6 m2 PASS [sizes] area/width minima: references/countries/sa.md 5.4 (residential code 5-4-2; row mapping flagged in file); other types generic rule of thumb (lower bound of architecture.md section 3 typical range) PASS [habitability] every habitable room has a window to OUTSIDE/courtyard; no WC/bath door straight into kitchen/dining/majlis PASS [privacy] no separate majlis/guest and family/bedroom zones to compare SUMMARY: 7 pass, 0 warn, 0 fail