Project dashboard

Sample Shopping Mall

مركز تسوق نموذجي

Pipeline

  1. 01BriefDone
    94 rooms · 2 levels · assumptions listed
  2. 02Code checkReview
    4/4 code checks pass · audit 14 pass · 0 warn · 0 fail · ⚠ verify flags
  3. 03DrawingsReview
    inside zip only
  4. 04MEPReview
    MEP overlay in zip
  5. 05BIMReview
    IFC inside zip
  6. 06RenderMissing
    no render image
  7. 07QA reviewMissing
    no qa-review.md

Key numbers

10,800m²Plot area
6,866m²Footprint
63.6%Coverage
2Levels
94Rooms
6,593m²Gross lettable area
7 + 11Shops per level
42.1mMax travel to exit

Code check

4 PASS
CheckDesignLimitResult
South front setback15.45 m≥ 5.00 mPASS
North rear setback11.85 m≥ 3.00 mPASS
West side setback5.25 m≥ 3.00 mPASS
East side setback5.25 m≥ 3.00 mPASS
Source: ASSUMED 5/3/3 m - no commercial-zone setbacks in country file [verify] ⚠ verify

Design parameters

Travel distance to exitmax 42.1 m ≤ 45 mPASSdefault 45 m sprinklered - number not in country file (verify with authority) ⚠ verify
Parking shown vs required45 of 264 baysWARNrule of thumb 4 bays per 100 m2 GLA ⚠ verify
Stair clear width1.20 mPASSrule of thumb 1200 mm clear ⚠ verify
Ground-floor height5.0 mPASSrule of thumb 4.5-5.5 m GF floor-to-floor ⚠ verify
Sprinkler designNFPA 13 OH2 · 12.1 m² / 4.6 mPASSreferences/disciplines/mep.md 4.1

Notes & assumptions

  • SAMPLE PROJECT generated by ArchMind gen_mall.py - not for submission.
  • GRID 8.4 m [RoT retail 7.5-9 m]; street 12 m, shops 8.4 x 21 m, service corridor 4.2 m [RoT].
  • TRAVEL LIMIT 45 m: default 45 m sprinklered - number not in country file (verify with authority) (verify). Computed max this level 42.1 m.
  • Exit = final exit door or protected-stair door; path around atrium void; open-plan rooms; sprinklered building (assumed).
  • SETBACKS F/S/R 5/3/3 m: ASSUMED 5/3/3 m - no commercial-zone setbacks in country file (verify)
  • ASSUMPTIONS: plot 120 x 90 m, frontage south, loading yard north; service corridors fire-rated, 2+ exits each.
  • WC separated men/women, accessible WC every level (RoT).
  • Stairs, escalators, atrium void: see MEP/ARCH overlay.

Design audit

7 PASS
ResultCheckFinding
PASSrooms45 rooms matched to 45 enclosed polygons; net areas within 5% of spec
PASScirculation119 doors; all 45 rooms reachable from OUTSIDE
PASSdoors119 doors / 35 windows: placement, swings and overlaps OK
PASSdead-spaceno dead-end corridor/hall over 6 m2
PASSsizesarea/width minima: no room-size number in references/countries/cn.md -> generic rule of thumb (lower bound of architecture.md section 3 typical range)
PASShabitabilityevery habitable room has a window to OUTSIDE/courtyard; no WC/bath door straight into kitchen/dining/majlis
PASSprivacynot applicable (country 'cn' is not a Gulf profile)

Verification

IFC modelvalid
Wall
60
Door
119
Window
35
OpeningElement
154
Slab
5
Space
45
Validation issues
0

Room schedule

RoomArea m²
MALL STREET & ATRIUM1,490.8
LIFTS10.8
LIFTS10.8
ANCHOR STORE W1,026.2
ANCHOR STORE E1,026.2
SERVICE CORRIDOR SW165.4
SERVICE CORRIDOR SE265.4
SERVICE CORRIDOR NW1131.5
SERVICE CORRIDOR NE298.3
ESCAPE STAIR 166.4
PASSAGE 145.4
ELEC RISER 141.8
MECH RISER 142.0
SHOP 01170.0
SHOP 02170.6
ESCAPE STAIR 266.4
PASSAGE 245.4
ELEC RISER 241.8
MECH RISER 242.0
SHOP 03170.0
SHOP 04170.0
SHOP 05170.0
SHOP 06170.6
LINK28.4
ACCESS WC5.7
MEN WC30.1
WOMEN WC29.8
BABY CARE34.5
FIRST AID34.2
MDB82.0
FIRE PUMP82.0
LOADING BAY203.1
AHU PLANT82.0
GEN SET82.0
LINK28.4
ACCESS WC5.7
MEN WC29.8
WOMEN WC30.1
BABY CARE34.2
FIRST AID34.5
SHOP 07170.0
ESCAPE STAIR 366.4
PASSAGE 345.4
ELEC RISER 341.8
MECH RISER 342.0
Total · 45 rooms6,559.9

Downloads

FileLevelSize
JSONGF.jsonGF37.8 KB
TXTGF-audit.txtGF724 B
JSONL1.jsonL134.2 KB
TXTL1-audit.txtL1724 B
JSONmall.jsonProject2.6 KB
ZIPdxf-ifc.zip
3 files: GF.dxf, GF-MEP.dxf, GF.ifc
Project179.5 KB
TXTifc.txtProject159 B
7 files255.6 KB